• New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
  • New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
  • New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System

New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System

Type: Security Alarm Host
Function: Software
Usage: Fire, Smoke
Certification: CE, En54 Certificate
Alarm Volume (within 1m): ≥90dB
Receive Frequency: 80Hz-18kHz
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PV-MCU EN54
Wiring Mode
Sub-Line System
Power
760W
Product Name
Main Control Unit
Main Supply Voltage
AC 220-240V, 50/60Hz
Backup Power Supply Voltage
AC 220-240V, 50/60Hz
Main Power Supply Fuse
T10ah 250V
Mic Input Sensitivity
-59+/-3dbv
Input Impedance
250 Ohm
Channels
2
Aux Input Sensitivity
1V(0dbv)
Aux Input Impedance
10K Ohm
Call Input Signal
2V
Package Dimension (W*H*D)
580*279*552mm
Transport Package
Box, Package or Carton
Specification
482*133.5*420mm
Trademark
Lucky Tone
Origin
Guangzhou, China
Production Capacity
5000/Month

Product Description

New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
New Arrival Product PV-MCU EN54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System 

Model Number: PV-MCU EN54

Description:

Master Control Unit (MCU) is the central management device of the system, which is used to manage and monitor all devices and performvarious operations. MCU is integrated with audio storage, broadcast, zone control, monitor, timing control, fault diagnosis, etc. functions. Built-in 500W digital power amplifier can drive maximum 8 loudspeaker lines to meet requirements for small applications. It can also be connected to zone expanders to increase system capacity for the requirements of large applications as well.

Features:
  1. Complies to international standards.
  2. Plug-and-play for easy commissioning.
  3. Fully configurable keys to achieve any task at the press of a button.
  4. Modular architecture: Expandable up to 128 speaker lines.
  5. Dual channel audio capability.
  6. Flexible amplifier backup modes to ensure low cost of ownership and high reliability.
  7. Digital volume control on all inputs/outputs.
  8. Comprehensive fault detection and indication.
  9. With EN54 certificate




                 New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System




   



New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System


New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System     
Specification  PV-MCU EN54
 Parameters  Values
 Main Supply Voltage   AC 220-240V, 50/60Hz
 Backup Power Supply Voltage  AC 220-240V, 50/60Hz
 Main Power Supply Fuse  T10AH 250V
 Power Consumption  <760W
 Microphone Input
 Input Sensitivity  -59±3dBV
 Input Impedance  250Ω
 Frequency Response  100Hz-14KHz, ±3dB
 SNR  >50dB
 Auxiliary Input
 Channels  2
 Input Sensitivity  1V(0dBV)
 Input Impedance  10 KΩ
 Frequency Response  85Hz-18KHz, ±3dB
 SNR  >80dB, A-weighted
 Phantom Power  24V DC, set by DIP switch
 Call Station Interface
 Input Signal  2V
 Input Impedance  20KΩ
 Output Signal  2V
 Onput Impedance  20KΩ
 Frequency Response  85Hz-18KHz
 Audio Output
 Output Channels  Channel 1, channel 2 and recording output
 Output Signal   1V(0dBV)
 THD  <0.1%
 Amplifier Control Interface
 Channels  3 (channel 1, channel 2 and backup amplifier)
 Output Signal  1.4V
 THD  <0.1%
 Control Signal   Self-test Signal, amplifier fault, signal and power saving control signal
 Loudspeaker Circuit
 Output Channels  8 (with group A and Group B)
 Maximum Loudspeaker Load  500W
 Contact Input / Output
 Contact Inputs  10 contact input interfaces with supervision
 Contact Outputs  8 (NO, NC&COM), fault output, emergency output
 Max. Working Voltage for Output  AC 250V/ DC 30V
 Max. Working Current for Output  2.5A
 Others
 DC Power Output  24V/1A
 Monitoring Loudspeaker  2W/8Ω
 Ethernet Port  10M/100M
 Memory Capacity  1GB flash memory, 4GB SD card
 Operating Conditions
 Humidity  <95%, without condensation
 Operating Temperature  -10ºC~+50ºC(14ºF to +122ºF)
 Storage Temperature   -40ºC~+70ºC(-40ºF to +158ºF)
 Weights and Dimensions  
 Product Dimension (W*H*D)  482*133.5*420mm
 Package Dimension (W*H*D)  580*279*552mm
 Net Weight  14.3KG
 Gross Weight  17.4KG
         
                                                                                        
New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System
New Arrival Product PV-MCU En54 Main Function Control Unit with Audio Storage and Monitor for Fire Alarm System



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
29
Year of Establishment
2016-12-09